IFM PN3129 压力传感器

IFM

IFM PN3129 压力传感器

带显示屏的压力传感器

IFM PN3129 压力传感器 — datasheet、规格参数、订货号查询与原装正品采购

获取报价 / 询盘

立即询价 WhatsApp 询盘 邮件询价

产品亮点

产品概述

产品标识电子压力传感器
应用用于工业应用
系统接口螺纹连接 G 1/4 内螺纹 M6 I
工作电压DC18...30 V
电压类型DC
电气设计PNP
输出数量2
输出功能常开/常闭; (可设定参数); 模拟
输出信号开关信号; 模拟信号; IO-Link; (可配置)
模拟电流输出4...20 mA
模拟电压输出0...10 V
测量范围-1...0 bar-1000...0 mbar-14.5...0 psi-29.5...0 inHg-100...0 kPa
接口M12 接插件
原材料不锈钢(1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
材料(接液部件)不锈钢(1.4404 / 316L); Al2O3 (陶瓷); FKM
显示显示单位: 4 x LED 绿色 (mbar, psi, kPa, inHg); 开关状态: 1 x LED 黄色; 测量值: 字母数字显示 红色/绿色 4位数字
环境温度-25...80 °C
介质温度-25...80 °C
通信接口IO-Link
产品易福门或同价值的
型号PN3129

技术规格

Product characteristics
Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range-1...0 bar -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa
Process connectionthreaded connection G 1/4 internal thread M6 I
Application
Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C]-25...80
Min. burst pressure50000 mbar 725 psi 1450 inHg 5000 kPa
Pressure rating20000 mbar 290 psi 590 inHg 2000 kPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum
Electrical data
Operating voltage[V]18...30 DC; (to SELV/PELV)
Current consumption[mA]< 35
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V]2.5
Permanent current rating of switching output DC[mA]150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz]< 170
Number of analogue outputs1
Analogue current output[mA]4...20
Max. load[Ω]500
Analogue voltage output[V]0...10
Min. load resistance[Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range-1...0 bar -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa
Factory setting / CMPT = 2
Set point SP-990...0 mbar -14.4...0 psi -29.3...0 inHg -99...0 kPa
Reset point rP-995...-5 mbar -14.45...-0.05 psi -29.4...-0.1 inHg -99.5...-0.5 kPa
Min. difference between SP and rP5 mbar 0.1 psi 0.2 inHg 0.5 kPa
In steps of5 mbar 0.05 psi 0.1 inHg 0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP-992...0 mbar -14.38...0 psi -29.3...0 inHg -99.2...0 kPa
Reset point rP-997...-5 mbar -14.45...-0.07 psi -29.4...-0.1 inHg -99.7...-0.5 kPa
Min. difference between SP and rP5 mbar 0.08 psi 0.2 inHg 0.5 kPa
In steps of1 mbar 0.01 psi 0.1 inHg 0.1 kPa
Accuracy / deviations
Switch point accuracy[% of the span]< ± 0,5
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]< ± 0,25
Long-term stability[% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Response times
Response time[ms]< 3
Delay time programmable dS, dr[s]0...50
Damping process value dAP[s]0...4
Damping for the analogue output dAA[s]0...4
Max. response time analogue output[ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary1
Supported DeviceIDs
Type of operationDeviceID
Factory setting / CMPT = 2434
Status_B High Resolution / CMPT = 3619
NoteFor further information please see the IODD PDF file under "Downloads"
Factory setting / CMPT = 2
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
Min. process cycle time[ms]2.3
IO-Link resolution pressure
1 mbar0.001 MPa
IO-Link process data (cyclical)
functionbit length
pressure14
binary switching information1
IO-Link functions (acyclical)application specific tag
Status_B High Resolution / CMPT = 3
Profiles
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
Min. process cycle time[ms]3
IO-Link resolution pressure
0.5 mbar0.0005 MPa
IO-Link process data (cyclical)
functionbit length
pressure16
device status4
binary switching information1
IO-Link functions (acyclical)application specific tag
Operating conditions
Ambient temperature[°C]-25...80
Storage temperature[°C]-40...100
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years]226
UL approval
UL approval no.J004
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]234.5
Housingcylindrical
Dimensions[mm]Ø 34 / L = 90.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 internal thread M6 I
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
Display
Display unit4 x LED, green (mbar, psi, kPa, inHg)
switching status1 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
Connector1 x M12; coding: A; Contacts: 4, gold-plated

下载资料