IFM PN2043 压力传感器

IFM

IFM PN2043 压力传感器

带显示屏的压力传感器

IFM PN2043 压力传感器 — datasheet、规格参数、订货号查询与原装正品采购

获取报价 / 询盘

立即询价 WhatsApp 询盘 邮件询价

产品亮点

产品概述

产品标识电子压力传感器
应用用于工业应用
系统接口螺纹连接 G 1/4 内螺纹 (DIN EN ISO 1179-2)
工作电压DC18...30 V
电压类型DC
电气设计PNP/NPN
输出数量2
输出功能常开/常闭; (可设定参数); 模拟
输出信号开关信号; 模拟信号; IO-Link; (可配置)
模拟电流输出4...20; (可调整量程 1:5) mA
模拟电压输出0...10; (可调整量程 1:5) V
测量范围0...40 bar0...580 psi0...4 MPa
接口M12 接插件
原材料不锈钢(1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
材料(接液部件)不锈钢(1.4404 / 316L); Al2O3 (陶瓷); FKM
显示显示单位: 3 x LED 绿色 (bar, psi, MPa); 开关状态: 2 x LED 黄色; 测量值: 字母数字显示 红色/绿色 4位数字
环境温度-25...80 °C
介质温度-25...80 °C
通信接口IO-Link
产品易福门或同价值的
型号PN2043

技术规格

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0...40 bar 0...580 psi 0...4 MPa
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C]-25...80
Min. burst pressure500 bar 7200 psi 50 MPa
Pressure rating200 bar 3000 psi 20 MPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressurerelative pressure
Electrical data
Operating voltage[V]18...30 DC; (to SELV/PELV)
Current consumption[mA]< 35
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V]2
Permanent current rating of switching output DC[mA]250
Switching frequency DC[Hz]< 500
Number of analogue outputs1
Analogue current output[mA]4...20; (scalable 1:5)
Max. load[Ω]500
Analogue voltage output[V]0...10; (scalable 1:5)
Min. load resistance[Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range0...40 bar 0...580 psi 0...4 MPa
Set point SP0.3...40 bar 5...580 psi 0.032...4 MPa
Reset point rP0.1...39.8 bar 2...577 psi 0.012...3.98 MPa
Analogue start point0...32 bar 0...464 psi 0...3.2 MPa
Analogue end point8...40 bar 116...580 psi 0.8...4 MPa
Min. difference between SP and rP0.2 bar 3 psi 0.02 MPa
In steps of0.1 bar 1 psi 0.001 MPa
Accuracy / deviations
Switch point accuracy[% of the span]< ± 0,8; (Turn down 1:1)
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span]< ± 0,4 (BFSL) / < ± 0,8 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time[ms]< 1.5
Delay time programmable dS, dr[s]0...50
Damping process value dAP[s]0...4
Damping for the analogue output dAA[s]0...4
Max. response time analogue output[ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
Profiles
Smart Sensor - SSP 3.1Measuring Sensor
Common - I&DIdentification and Diagnosis
SIO modeyes
Required master port typeA; (when pin 2 not connected: B)
Min. process cycle time[ms]3
IO-Link resolution pressure[bar]0.02
IO-Link process data (cyclical)
functionbit length
pressure16
device status4
binary switching information2
IO-Link functions (acyclical)application specific tag
Supported DeviceIDs
Type of operationDeviceID
default1201
NoteFor further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature[°C]-25...80
Storage temperature[°C]-40...100
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years]166
UL approval
UL approval no.J013
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]282.5
Housingcylindrical
Dimensions[mm]Ø 34 / L = 90.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
Connector1 x M12; coding: A; Contacts: 4, gold-plated