IFM PE2593 压力传感器

IFM

IFM PE2593 压力传感器

带显示屏的压力传感器

IFM PE2593 压力传感器 — datasheet、规格参数、订货号查询与原装正品采购

获取报价 / 询盘

立即询价 WhatsApp 询盘 邮件询价

产品亮点

产品概述

产品标识电子压力传感器
应用用于工业应用
系统接口螺纹连接 G 1/4 外螺纹 内螺纹:M5; DIN EN ISO 1179-2
工作电压DC18...30 V
电压类型DC
电气设计PNP/NPN
输出数量2
输出功能常开/常闭; (可设定参数); 模拟
输出信号开关信号; 模拟信号; IO-Link; (可配置)
模拟电流输出4...20; (可调整量程 1:5) mA
模拟电压输出0...10; (可调整量程 1:5) V
测量范围-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
接口M12 接插件
原材料不锈钢(1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM
材料(接液部件)不锈钢(1.4404 / 316L); Al2O3 (99.9 %; 陶瓷); EPDM
显示显示单位: 3 x LED 绿色 (bar, psi, MPa); 开关状态: 2 x LED 黄色; 测量值: 字母数字显示 红色/绿色 4位数字
环境温度-25...80 °C
介质温度-25...80 °C
通信接口IO-Link
产品易福门或同价值的
型号PE2593

技术规格

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range-1...25 bar -14.5...362.5 psi -0.1...2.5 MPa
Process connectionthreaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2
Application
Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C]-25...80
Min. burst pressure350 bar 5075 psi 35 MPa
Pressure rating150 bar 2175 psi 15 MPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressurerelative pressure
Electrical data
Operating voltage[V]18...30 DC; (to SELV/PELV)
Current consumption[mA]< 35
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V]2
Permanent current rating of switching output DC[mA]250
Switching frequency DC[Hz]< 500
Number of analogue outputs1
Analogue current output[mA]4...20; (scalable 1:5)
Max. load[Ω]500
Analogue voltage output[V]0...10; (scalable 1:5)
Min. load resistance[Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range-1...25 bar -14.5...362.5 psi -0.1...2.5 MPa
Set point SP-0.85...25 bar -12...362.5 psi -0.085...2.5 MPa
Reset point rP-0.95...24.9 bar -13.5...361 psi -0.095...2.49 MPa
Analogue start point-1...20 bar -14.5...290 psi -0.1...2 MPa
Analogue end point4...25 bar 58...362.5 psi 0.4...2.5 MPa
In steps of0.05 bar 0.5 psi 0.005 MPa
Accuracy / deviations
Switch point accuracy[% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K]0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K]0,2; (-25...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time[ms]< 1.5
Delay time programmable dS, dr[s]0...50
Damping process value dAP[s]0...4
Damping for the analogue output dAA[s]0...4
Max. response time analogue output[ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary2
Min. process cycle time[ms]2.3
Supported DeviceIDs
Type of operationDeviceID
default462
Operating conditions
Ambient temperature[°C]-25...80
Storage temperature[°C]-40...100
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years]161
UL approval
UL approval no.J012
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]261
Housingcylindrical
Dimensions[mm]Ø 34 / L = 92.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; EPDM
Materials (wetted parts)stainless steel (316L/1.4404); Al2O3 (99.9%; ceramics); EPDM
Min. pressure cycles100 million
Tightening torque[Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2
Process connection sealingEPDM
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
Connector1 x M12; coding: A; Contacts: 4, gold-plated

下载资料