IFM

IFM O1D100 激光测距传感器

激光测距传感器

IFM O1D100 激光测距传感器 — datasheet、规格参数、订货号查询与原装正品采购

获取报价 / 询盘

立即询价 WhatsApp 询盘 邮件询价

产品亮点

产品概述

产品标识激光测距传感器
应用工业应用/工厂自动化
电压类型DC
工作电压DC18...30 V
电气设计PNP
输出功能常开/常闭; (可设定参数); 模拟
透镜校准侧面的镜组
测量范围0.2...10 m
激光防护等级2
接口M12 接插件
原材料外壳: 模压铸锌; 前面透镜: 玻璃; LED窗口: PC
显示开关状态: 2 x LED 黄色; 操作: LED 绿色; 距离, 编程: 字母数字显示 4位数字
外壳防护等级IP 67
环境温度-10...60 °C
通信接口IO-Link
产品易福门或同价值的
型号O1D100

技术规格

Product characteristics
Laser protection class2
Housingrectangular
Application
ApplicationIndustrial applications / factory automation
Electrical data
Operating voltage[V]18...30 DC; ("supply class 2" to cULus)
Current consumption[mA]< 150
Protection classIII
Reverse polarity protectionyes
Typ. lifetime[h]50000
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. current load per output[mA]200
Number of analogue outputs1
Analogue current output[mA]4...20; (IEC 61131-2)
Max. load[Ω]250
Analogue voltage output[V]0...10; (IEC 61131-2)
Min. load resistance[Ω]5000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Max. light spot diameter[mm]25
Light spot dimensions refer to10 m
Background suppression[m]0...19
Measuring/setting range
Measuring range[m]0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate[Hz]1...50
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
Profiles
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice identification
FunctionProcess data variable
FunctionDevice diagnosis
FunctionTeach channel
SIO modeyes
Required master port typeA
Process data analogue2
Process data binary3
Min. process cycle time[ms]5
Supported DeviceIDs
Type of operationDeviceID
default806
Operating conditions
Ambient temperature[°C]-10...60
ProtectionIP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class2
Notes on laser protection
Caution:laser light
Power:<= 4 mW
Wave length:650 nm
pulse:1,3 ns
Do not stare into beam.
Avoid exposure to the laser light.
laser class:2 EN / IEC60825-1:2007 EN / IEC60825-1:2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
MTTF[years]182
Mechanical data
Weight[g]243.5
Housingrectangular
Dimensions[mm]59 x 42 x 52
Materialshousing: diecast zinc; front pane: glass; LED window: PC
Lens alignmentside lens
Displays / operating elements
Display
switching status2 x LED, yellow
operationLED, green
distance value, programmingalphanumeric display, 4-digit
Accessories
Accessories (optional)Protective cover, E21133
Remarks
Remarks
For more information about the measuring range / application please refer to the operating instructions.
Pack quantity1 pcs.
Electrical connection - plug
Connector1 x M12; coding: A; Contacts: 5
Other data
ParameterSetting range Factory setting
Unimm, m, inch mm
OU1Hno, Hnc, Fno, Fnc Hno
SP1 [mm]200...9999 1000
nSP1 [mm]200...9999 800
FSP1 [mm]200...9999 1200
OU2Hno, Hnc, Fno, Fnc, I, U I
SP2 [mm]200...9999 2000
nSP2 [mm]200...9999 1800
FSP2 [mm]200...9999 2200
ASP [mm]0...9999 0
AEP [mm]0...9999 9999
rATE [Hz]1...50 50
dS1 [s]0...0.1...5 0
dr1 [s]0...0.1...5 0
dS2 [s]0...0.1...5 0
dr2 [s]0...0.1...5 0
dFo [s]0...0.1...5 0
dISd1...3 ; rd1...3; OFF d3
repeatability/accuracy
distancerepeatability of the measured values accuracy
white (90 % remission)grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm± 5.0 mm ±7.5 mm ± 15.0 mm ± 18.0 mm
1000...2000 mm± 5.5 mm ±10.0 mm ± 15.0 mm ± 20.0 mm
2000...4000 mm± 17.5 mm ±22.5 mm ± 25.0 mm ± 32.0 mm
4000...6000 mm± 27.5 mm ±40.0 mm ± 35.0 mm ± 50.0 mm
6000...10000 mm± 60.0 mm ± 70.0mm
Sampling rate50 Hz
Extraneous light on the object< 40 klx
repeatability/accuracy
distancerepeatability of the measured values accuracy
white (90 % remission)grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
1000...2000 mm± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm
2000...4000 mm± 30.0 mm ±37.0 mm ± 40.0 mm ± 47.0 mm
4000...6000 mm± 37.0 mm ±57.0 mm ± 47.0 mm ± 67.0 mm
6000...10000 mm± 75.0 mm — ± 85.0mm —
Sampling rate50 Hz
Extraneous light on the object40...100 klx
repeatability/accuracy
distancerepeatability of the measured values accuracy
white (90 % remission)grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm± 4.0 mm ±4.5 mm ± 14.0 mm ± 15.0 mm
1000...2000 mm± 4.5 mm ±6.0 mm ± 14.5 mm ± 16.0 mm
2000...4000 mm± 13.5 mm ±14.5 mm ± 23.5 mm ± 24.0 mm
4000...6000 mm± 19.0 mm ±21.0 mm ± 29.0 mm ± 31.0 mm
6000...10000 mm± 37.0 mm – ± 47.0mm –
Sampling rate1 Hz
Extraneous light on the object< 40 klx
repeatability/accuracy
distancerepeatability of the measured values accuracy
white (90 % remission)grey (18 % remission) white (90 % remission) grey (18 % remission)
200...1000 mm± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
1000...2000 mm± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm
2000...4000 mm± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm
4000...6000 mm± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm
6000...10000 mm± 37.0 mm – ± 47.0mm –
Sampling rate1 Hz
Extraneous light on the object< 40...100 klx
Range on black object (6 % remission)<= 4000 mm
The values apply at
constant ambient conditions23 °C / 960 hPa
minimum power-on time in minutes10