产品亮点
- 可靠的光学距离测量,量程最高可达 10 m
- 2 个开关输出;可将其中一个编程为模拟输出
- 可调整的测量范围和窗口功能
- 适用于需背景抑制功能的应用
- 极高的性价比
产品概述
| 产品标识 | 激光测距传感器 |
| 应用 | 工业应用/工厂自动化 |
| 电压类型 | DC |
| 工作电压DC | 18...30 V |
| 电气设计 | PNP |
| 输出功能 | 常开/常闭; (可设定参数); 模拟 |
| 透镜校准 | 侧面的镜组 |
| 测量范围 | 0.2...10 m |
| 激光防护等级 | 2 |
| 接口 | M12 接插件 |
| 原材料 | 外壳: 模压铸锌; 前面透镜: 玻璃; LED窗口: PC |
| 显示 | 开关状态: 2 x LED 黄色; 操作: LED 绿色; 距离, 编程: 字母数字显示 4位数字 |
| 外壳防护等级 | IP 67 |
| 环境温度 | -10...60 °C |
| 通信接口 | IO-Link |
| 产品 | 易福门或同价值的 |
| 型号 | O1D100 |
技术规格
| Product characteristics | |
| Laser protection class | 2 |
| Housing | rectangular |
| Application | |
| Application | Industrial applications / factory automation |
| Electrical data | |
| Operating voltage[V] | 18...30 DC; ("supply class 2" to cULus) |
| Current consumption[mA] | < 150 |
| Protection class | III |
| Reverse polarity protection | yes |
| Typ. lifetime[h] | 50000 |
| Inputs / outputs | |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs | |
| Total number of outputs | 2 |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. current load per output[mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] | 4...20; (IEC 61131-2) |
| Max. load[Ω] | 250 |
| Analogue voltage output[V] | 0...10; (IEC 61131-2) |
| Min. load resistance[Ω] | 5000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone | |
| Max. light spot diameter[mm] | 25 |
| Light spot dimensions refer to | 10 m |
| Background suppression[m] | 0...19 |
| Measuring/setting range | |
| Measuring range[m] | 0.2...10; (white paper 200 x 200 mm 90% remission) |
| Sampling rate[Hz] | 1...50 |
| Interfaces | |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device identification |
| Function | Process data variable |
| Function | Device diagnosis |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 3 |
| Min. process cycle time[ms] | 5 |
| Supported DeviceIDs | |
| Type of operation | DeviceID |
| default | 806 |
| Operating conditions | |
| Ambient temperature[°C] | -10...60 |
| Protection | IP 67 |
| Tests / approvals | |
| EMC | |
| EN 60947-5-2 | |
| Laser protection class | 2 |
| Notes on laser protection | |
| Caution: | laser light |
| Power: | <= 4 mW |
| Wave length: | 650 nm |
| pulse: | 1,3 ns |
| Do not stare into beam. | |
| Avoid exposure to the laser light. | |
| laser class: | 2 EN / IEC60825-1:2007 EN / IEC60825-1:2014 |
| Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019. | |
| MTTF[years] | 182 |
| Mechanical data | |
| Weight[g] | 243.5 |
| Housing | rectangular |
| Dimensions[mm] | 59 x 42 x 52 |
| Materials | housing: diecast zinc; front pane: glass; LED window: PC |
| Lens alignment | side lens |
| Displays / operating elements | |
| Display | |
| switching status | 2 x LED, yellow |
| operation | LED, green |
| distance value, programming | alphanumeric display, 4-digit |
| Accessories | |
| Accessories (optional) | Protective cover, E21133 |
| Remarks | |
| Remarks | |
| For more information about the measuring range / application please refer to the operating instructions. | |
| Pack quantity | 1 pcs. |
| Electrical connection - plug | |
| Connector | 1 x M12; coding: A; Contacts: 5 |
| Other data | |
| Parameter | Setting range Factory setting |
| Uni | mm, m, inch mm |
| OU1 | Hno, Hnc, Fno, Fnc Hno |
| SP1 [mm] | 200...9999 1000 |
| nSP1 [mm] | 200...9999 800 |
| FSP1 [mm] | 200...9999 1200 |
| OU2 | Hno, Hnc, Fno, Fnc, I, U I |
| SP2 [mm] | 200...9999 2000 |
| nSP2 [mm] | 200...9999 1800 |
| FSP2 [mm] | 200...9999 2200 |
| ASP [mm] | 0...9999 0 |
| AEP [mm] | 0...9999 9999 |
| rATE [Hz] | 1...50 50 |
| dS1 [s] | 0...0.1...5 0 |
| dr1 [s] | 0...0.1...5 0 |
| dS2 [s] | 0...0.1...5 0 |
| dr2 [s] | 0...0.1...5 0 |
| dFo [s] | 0...0.1...5 0 |
| dIS | d1...3 ; rd1...3; OFF d3 |
| repeatability/accuracy | |
| distance | repeatability of the measured values accuracy |
| white (90 % remission) | grey (18 % remission) white (90 % remission) grey (18 % remission) |
| 200...1000 mm | ± 5.0 mm ±7.5 mm ± 15.0 mm ± 18.0 mm |
| 1000...2000 mm | ± 5.5 mm ±10.0 mm ± 15.0 mm ± 20.0 mm |
| 2000...4000 mm | ± 17.5 mm ±22.5 mm ± 25.0 mm ± 32.0 mm |
| 4000...6000 mm | ± 27.5 mm ±40.0 mm ± 35.0 mm ± 50.0 mm |
| 6000...10000 mm | ± 60.0 mm ± 70.0mm |
| Sampling rate | 50 Hz |
| Extraneous light on the object | < 40 klx |
| repeatability/accuracy | |
| distance | repeatability of the measured values accuracy |
| white (90 % remission) | grey (18 % remission) white (90 % remission) grey (18 % remission) |
| 200...1000 mm | ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm |
| 1000...2000 mm | ± 16.5 mm ±16.5 mm ± 26.5 mm ± 26.5 mm |
| 2000...4000 mm | ± 30.0 mm ±37.0 mm ± 40.0 mm ± 47.0 mm |
| 4000...6000 mm | ± 37.0 mm ±57.0 mm ± 47.0 mm ± 67.0 mm |
| 6000...10000 mm | ± 75.0 mm — ± 85.0mm — |
| Sampling rate | 50 Hz |
| Extraneous light on the object | 40...100 klx |
| repeatability/accuracy | |
| distance | repeatability of the measured values accuracy |
| white (90 % remission) | grey (18 % remission) white (90 % remission) grey (18 % remission) |
| 200...1000 mm | ± 4.0 mm ±4.5 mm ± 14.0 mm ± 15.0 mm |
| 1000...2000 mm | ± 4.5 mm ±6.0 mm ± 14.5 mm ± 16.0 mm |
| 2000...4000 mm | ± 13.5 mm ±14.5 mm ± 23.5 mm ± 24.0 mm |
| 4000...6000 mm | ± 19.0 mm ±21.0 mm ± 29.0 mm ± 31.0 mm |
| 6000...10000 mm | ± 37.0 mm – ± 47.0mm – |
| Sampling rate | 1 Hz |
| Extraneous light on the object | < 40 klx |
| repeatability/accuracy | |
| distance | repeatability of the measured values accuracy |
| white (90 % remission) | grey (18 % remission) white (90 % remission) grey (18 % remission) |
| 200...1000 mm | ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm |
| 1000...2000 mm | ± 10.0 mm ± 10.0 mm ± 20.0 mm ± 20.0 mm |
| 2000...4000 mm | ± 17.0 mm ± 18.0 mm ± 27.0 mm ± 28.0 mm |
| 4000...6000 mm | ± 22.0 mm ± 25.0 mm ± 32.0 mm ± 35.0 mm |
| 6000...10000 mm | ± 37.0 mm – ± 47.0mm – |
| Sampling rate | 1 Hz |
| Extraneous light on the object | < 40...100 klx |
| Range on black object (6 % remission) | <= 4000 mm |
| The values apply at | |
| constant ambient conditions | 23 °C / 960 hPa |
| minimum power-on time in minutes | 10 |