SICK WTB4SC-3P2262VB01 Photoelectric Sensors

SICK

SICK WTB4SC-3P2262VB01 Photoelectric Sensors

P/N: 1115584

SICK WTB4SC-3P2262VB01 Photoelectric Sensors — datasheet, specifications, part number lookup & authentic sourcing

Get a Quote / Inquire

Request a Quote Chat via WhatsApp Email Us

Overview

Functional principlePhotoelectric proximity sensor
Functional principle detailBackground suppression
Sensing range max.4 mm ... 500 mm 1)
Sensing range10 mm ... 350 mm 1) Emitted beam
Light sourcePinPoint LED 2)
Type of lightVisible red light
Light spot size (distance)Ø 6.5 mm (150 mm) Key LED figures
Wave length650 nm
AdjustmentSingle teach-in button
Special applicationsHygienic and washdown zones
Housing designWashdown
Pin 2 configurationExternal input, Teach-in input, Sender off input, Detection output, logic output 1) Object with 90% remission (based on standard white, DIN 5033).2) Average service life: 100,000 h at TU = +25 °C.

Specifications

Safety-related parameters
MTTFD868 years
DCavg0 % ## Communication interface
IO-Link✔ , IO-Link V1.1
Data transmission rateCOM2 (38,4 kBaud)
Cycle time2.3 ms
Process data length16 Bit
Process data structureBit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 ... 15 = empty
VendorID26
DeviceID HEX0x8001E6
DeviceID DEC8389094
Compatible master port typeA
SIO mode supportYes
Electronics
Supply voltage UB10 V DC ... 30 V DC 1)
Ripplepp 2)
Current consumption30 mA 3)
Protection classIII Digital output
TypePNP 4)
Switching modeLight/dark switching
Output current Imax.≤ 100 mA
Response time5)
Repeatability (response time)150 µs 6)
Switching frequency1,000 Hz 7)
Output functionComplementary
Circuit protectionA 8)B 9)C 10)
Response time Q/ on Pin 2300 µs ... 450 µs 5) 6)
Switching frequency Q / to pin 21,000 Hz 11) 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.2) May not fall below or exceed UV tolerances.3) Without load.4) Pin 4: This switching output must not be connected to another output.5) Signal transit time with resistive load.6) Valid for Q \ on Pin2, if configured with software.7) With light/dark ratio 1:1.8) A = VS connections reverse-polarity protected.9) B = inputs and output reverse-polarity protected.10) C = interference suppression.11) With light / dark ratio 1:1, valid for Q \ on Pin2, if configured with software.
Mechanics
HousingRectangular
Design detailSlim
Dimensions (W x H x D)15.25 mm x 44.9 mm x 22.2 mm
ConnectionMale connector M8, 4-pin 1) Material
HousingMetal, Stainless steel V4A (1.4404, 316L)
Front screenPlastic, PMMA
Weight40 g 1) Max. tightening torque: 0.6 Nm.
Ambient data
Enclosure ratingIP66IP67IP68IP69K 1)
Ambient operating temperature–30 °C ... +70 °C 2)–30 °C ... +60 °C
Ambient temperature, storage–30 °C ... +75 °C
UL File No.NRKH.E181493 & NRKH7.E181493 1) Only in case of correctly mounted IP69K connecting cable.2) At UV ≤ 24 V and IA ## Smart Task
Smart Task nameBase logics
Logic functionDirectANDORWINDOWHysteresis
Timer functionDeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
InverterYes
Switching frequencySIO Direct: 1000 HzSIO Logic: 600 HzIOL: 450 Hz
Response timeSIO Direct: 300 µs ... 450 µs 1)SIO Logic: 750 µs ... 900 µs 2)IOL: 800 µs ... 1200 µs 3)
RepeatabilitySIO Direct: 150 µs 1)SIO Logic: 150 µs 2)IOL: 400 µs 3) Switching signal
Switching signal QL1Switching output
Switching signal QL2Switching output 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to "direct"/"deactivated").2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters. ## Diagnosis
Device statusYes ## Certificates
EU declaration of conformity
UK declaration of conformity
ACMA declaration of conformity
Moroccan declaration of conformity
China RoHS
China Compulsory Product Certification (CCC) exempt
ECOLAB certificate
Photobiological safety (DIN EN 62471) certificate
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)✔ ## Classifications
ECLASS 5.1.427270903
ECLASS 6.027270903
ECLASS 7.027270903
ECLASS 8.027270903
ECLASS 9.027270903
ECLASS 10.027270903
ECLASS 11.027270903
ECLASS 12.027270903
ECLASS 13.027270903
ECLASS 14.027270903
ECLASS 15.027270903
ETIM 6.0EC002719
ETIM 7.0EC002719
ETIM 8.0EC002719
ETIM 9.0EC002719
ETIM 10.0EC002719
UNSPSC 091201.032151804
UNSPSC 100501.032151804
UNSPSC 111201.032151804
UNSPSC 120901.032151804
UNSPSC 131201.032151804
UNSPSC 140801.032151804
UNSPSC 151101.032151804
UNSPSC 160901.032151804
UNSPSC 171001.032151804
UNSPSC 180801.032151804
UNSPSC 190501.032151804
UNSPSC 200601.032151804
UNSPSC 210901.032151804
UNSPSC 220601.032151804
UNSPSC 230701.032151804
UNSPSC 240301.032151804
UNSPSC 250901.032151804
UNSPSC 260801.032151804

Downloads