SICK WTB12C-3P2432A71 Photoelectric Sensors

SICK

SICK WTB12C-3P2432A71 Photoelectric Sensors

P/N: 1067773

SICK WTB12C-3P2432A71 Photoelectric Sensors — datasheet, specifications, part number lookup & authentic sourcing

Get a Quote / Inquire

Request a Quote Chat via WhatsApp Email Us

Overview

Functional principlePhotoelectric proximity sensor
Functional principle detailBackground suppression
Sensing range max.20 mm ... 350 mm 1)
Sensing range20 mm ... 350 mm 1) Emitted beam
Light sourcePinPoint LED 2)
Type of lightVisible red light
Light spot size (distance)Ø 6 mm (200 mm) Key LED figures
Wave length640 nm
AdjustmentIO-Link, Single teach-in button
Pin 2 configurationExternal input, Teach-in input, Sender off input, Detection output, logic output 1) Object with 90% remission (based on standard white, DIN 5033).2) Average service life: 50,000 h at TU = +25 °C.

Specifications

Safety-related parameters
MTTFD634 years
DCavg0 %
TM (mission time)20 years ## Communication interface
IO-Link✔ , IO-Link V1.1
Data transmission rateCOM2 (38,4 kBaud)
Cycle time2.3 ms
Process data length16 Bit
Process data structureBit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 ... 15 = measuring value
VendorID26
DeviceID HEX0x8000EC
DeviceID DEC8388844
Compatible master port typeA
SIO mode supportYes
Electronics
Supply voltage UB10 V DC ... 30 V DC 1)
Ripplepp 2)
Current consumption45 mA 3)
Protection classIII Digital output
TypePNP 4)
Switching modeLight/dark switching
Signal voltage PNP HIGH/LOW> Uv - 2,5 V / ca. 0 V
Output current Imax.≤ 100 mA
Response time5)
Repeatability (response time)100 µs 6)
Switching frequency1,500 Hz
Circuit protectionA 7)B 8)C 9)D 10)
Response time Q/ on Pin 2200 µs ... 300 µs 5) 6)
Switching frequency Q / to pin 2≤ 1,500 Hz 11) 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not fall below or exceed UV tolerances.3) Without load.4) Pin 4: This switching output must not be connected to another output.5) Signal transit time with resistive load.6) Valid for Q \ on Pin2, if configured with software.7) A = VS connections reverse-polarity protected.8) B = inputs and output reverse-polarity protected.9) C = interference suppression.10) D = outputs overcurrent and short-circuit protected.11) With light / dark ratio 1:1, valid for Q \ on Pin2, if configured with software.
Mechanics
HousingRectangular
Dimensions (W x H x D)15.6 mm x 48.5 mm x 42 mm
ConnectionMale connector M12, 4-pin Material
HousingMetal, zinc diecast
Front screenPlastic, PMMA
Weight120 g
Ambient data
Enclosure ratingIP66IP67
Ambient operating temperature–40 °C ... +60 °C
Ambient temperature, storage–40 °C ... +75 °C
UL File No.NRKH.E181493 & NRKH7.E181493 ## Smart Task
Smart Task nameCounter + debouncing
Logic functionDirectWINDOWHysteresis
Timer functionDeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
InverterYes
Maximum counting frequencySIO Direct: --- 1)SIO Logic: 1000 Hz 2)IOL: 650 Hz 3)
Counter resetSIO Direct: ---SIO Logic: 1,5 msIOL: 1,5 ms
Min. Time between two process events (switches)SIO Direct: ---SIO Logic: 500 µsIOL: 800 µs
Debounce time max.SIO Direct: ---SIO Logic: 30.000 msIOL: 30.000 ms Switching signal
Switching signal QL1Output type (dependant on the adjusted threshold)
Switching signal QL2Output type (dependant on the adjusted threshold)
Measuring valueCounting value 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to "direct"/"deactivated").2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters. ## Diagnosis
Device statusYes ## Certificates
EU declaration of conformity
UK declaration of conformity
ACMA declaration of conformity
Moroccan declaration of conformity
China RoHS
ECOLAB certificate
cULus certificate
IO-Link certificate
Photobiological safety (DIN EN 62471) certificate
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)✔ ## Classifications
ECLASS 5.1.427270903
ECLASS 6.027270903
ECLASS 7.027270903
ECLASS 8.027270903
ECLASS 9.027270903
ECLASS 10.027270903
ECLASS 11.027270903
ECLASS 12.027270903
ECLASS 13.027270903
ECLASS 14.027270903
ECLASS 15.027270903
ETIM 6.0EC002719
ETIM 7.0EC002719
ETIM 8.0EC002719
ETIM 9.0EC002719
ETIM 10.0EC002719
UNSPSC 091201.032151804
UNSPSC 100501.032151804
UNSPSC 111201.032151804
UNSPSC 120901.032151804
UNSPSC 131201.032151804
UNSPSC 140801.032151804
UNSPSC 151101.032151804
UNSPSC 160901.032151804
UNSPSC 171001.032151804
UNSPSC 180801.032151804
UNSPSC 190501.032151804
UNSPSC 200601.032151804
UNSPSC 210901.032151804
UNSPSC 220601.032151804
UNSPSC 230701.032151804
UNSPSC 240301.032151804
UNSPSC 250901.032151804
UNSPSC 260801.032151804

Downloads