SICK
SICK WL4SLC-3P2232A72 Photoelectric Sensors
P/N: 1098509
SICK WL4SLC-3P2232A72 Photoelectric Sensors — datasheet, specifications, part number lookup & authentic sourcing
Get a Quote / Inquire
Overview
| Functional principle | Photoelectric retro-reflective sensor |
| Functional principle detail | Without reflector minimum distance (autocollimation/coaxial optics) |
| Sensing range max. | 0 m ... 12 m 1) |
| Sensing range | 0 m ... 8 m 1) |
| Polarisation filter | Yes Emitted beam |
| Light source | Laser 2) |
| Type of light | Visible red light |
| Light spot size (distance) | Ø 1 mm (500 mm) Key laser figures |
| Normative reference | EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11 |
| Laser class | 1 3) |
| Wave length | 650 nm |
| Adjustment | IO-Link, Single teach-in button |
| Required accessories | Auxiliary sensor (e.g. WL4SL-3P2232, 1061561), Smart-Sensor Y-junction SYL-8204-G0M11-X2 (6055012), 2 x connecting cable (e.g. YF8U14-C60VA3M8U14, 2096612), 2 x reflector (e.g. P250F, 5308843) |
| Mounting hole | M3 1) Reflector PL80A.2) Average service life: 50,000 h at TU = +25 °C.3) Do not intentionally look into the laser beam. Never point the laser beam at people's eyes. |
Specifications
| Safety-related parameters | |
| MTTFD | 562 years (EN ISO 13849-1) 1) |
| DCavg | 0 % |
| TM (mission time) | 10 years 1) Mode of calculation: Parts-Count-calculation. ## Communication interface |
| IO-Link | ✔ , IO-Link V1.1 |
| Data transmission rate | COM2 (38,4 kBaud) |
| Cycle time | 2.3 ms |
| Process data length | 16 Bit |
| Process data structure | Bit 0 = switching signal QL1 Bit 1 = Detection signal Qint.1 Bit 2 ... 15 = measuring value |
| VendorID | 26 |
| DeviceID HEX | 0x800222 |
| DeviceID DEC | 8389154 |
| Compatible master port type | A |
| SIO mode support | Yes |
| Electronics | |
| Supply voltage UB | 10 V DC ... 30 V DC 1) |
| Ripple | pp 2) |
| Current consumption | 30 mA 3) |
| Protection class | III Digital output |
| Type | PNP 4) |
| Switching mode | Light/dark switching 4) |
| Output current Imax. | ≤ 100 mA |
| Response time | ≤ 0.5 ms 6) |
| Repeatability (response time) | 150 µs 7) |
| Switching frequency | 1,000 Hz 8) |
| Output function | Complementary |
| Circuit protection | A 9)B 10)C 11) |
| Response time Q/ on Pin 2 | 300 µs ... 450 µs 6) 7) |
| Switching frequency Q / to pin 2 | 1,000 Hz 12) 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not fall below or exceed UV tolerances.3) Without load.4) Q = light switching.5) Pin 4: This switching output must not be connected to another output.6) Signal transit time with resistive load.7) Valid for Q \ on Pin2, if configured with software.8) With light/dark ratio 1:1.9) A = VS connections reverse-polarity protected.10) B = inputs and output reverse-polarity protected.11) C = interference suppression.12) With light / dark ratio 1:1, valid for Q \ on Pin2, if configured with software. |
| Mechanics | |
| Housing | Rectangular |
| Design detail | Slim |
| Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
| Connection | Male connector M8, 4-pin Material |
| Housing | Plastic, Novodur |
| Front screen | Plastic, PMMA |
| Weight | 100 g |
| Ambient data | |
| Enclosure rating | IP66IP67 |
| Ambient operating temperature | –10 °C ... +50 °C |
| Ambient operating temperature extended | –30 °C ... +55 °C 1) 2) |
| Ambient temperature, storage | –30 °C ... +70 °C |
| UL File No. | NRKH.E181493 1) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.2) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible. ## Smart Task |
| Smart Task name | Speed and Length Monitoring |
| Measurement mode | SpeedLengthLength incremental |
| Relative measurement error related to the measured value | ≤ 1 % |
| Resolution measurement value | 1 mm / 1 mm/s |
| Logic function | WINDOW |
| Timer function | Impulse width, impulse shift |
| Max. pulse frequency at the external input (pin 2 / white wire) | ≤ 1,000 Hz Switching signal |
| Switching signal QL1 | Switching output to measuring value switching thresholds |
| Measuring value | Speed measurement value / length measurement value ## Diagnosis |
| Device status | Yes |
| Quality of teach | Yes |
| Quality of run | Yes, Contamination display ## Certificates |
| EU declaration of conformity | ✔ |
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| Moroccan declaration of conformity | ✔ |
| China RoHS | ✔ |
| China Compulsory Product Certification (CCC) exempt | ✔ |
| ECOLAB certificate | ✔ |
| Laser safety (IEC 60825-1) certificate | ✔ |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | ✔ ## Classifications |
Downloads
- datasheet WL4SLC-3P2232A72 (728 KB)