Functional principlePhotoelectric retro-reflective sensor
Functional principle detailWithout reflector minimum distance (autocollimation/coaxial optics)
Sensing range max.0 m ... 5 m 1)
Sensing range0 m ... 3 m 1)
Polarisation filterYes Emitted beam
Light sourcePinPoint LED 2)
Type of lightVisible red light
Light spot size (distance)Ø 45 mm (1.5 m)
AdjustmentIO-Link, Single teach-in button
Special featuresAuxiliary sensor (e.g. WL4S-3P2232, 1042078), Smart-Sensor Y-junction SYL-8204-G0M11-X2 (6055012), 2 x connecting cable (e.g. YF8U14-C60VA3M8U14, 2096612), 2 x reflector (e.g. P250F, 5308843) 1) Reflector PL80A.2) Average service life: 100,000 h at TU = +25 °C.

Specifications

Safety-related parameters
MTTFD1,222 years (EN ISO 13849-1) 1)
DCavg0%
TM (mission time)10 years 1) Mode of calculation: Parts-Count-calculation. ## Communication interface
IO-Link✔ , IO-Link V1.1
Data transmission rateCOM2 (38,4 kBaud)
Cycle time2.3 ms
Process data length16 Bit
Process data structureBit 0 = switching signal QL1 Bit 1 = Detection signal Qint.1 Bit 2 ... 15 = measuring value
VendorID26
DeviceID HEX0x8001B7
DeviceID DEC8389047
Compatible master port typeA
SIO mode supportYes
Electronics
Supply voltage UB10 V DC ... 30 V DC 1)
Ripplepp 2)
Current consumption30 mA 3)
Protection classIII Digital output
TypePNP 4)
Switching modeLight/dark switching 4)
Output current Imax.≤ 100 mA
Response time≤ 0.5 ms 6)
Repeatability (response time)150 µs 7)
Switching frequency1,000 Hz 8)
Output functionComplementary
Circuit protectionA 9)B 10)C 11) 1) Limit values when operated in short-circuit protected network: max. 8 A.2) May not fall below or exceed UV tolerances.3) Without load.4) Q = light switching.5) Pin 4: This switching output must not be connected to another output.6) Signal transit time with resistive load.7) Valid for Q \ on Pin2, if configured with software.8) With light/dark ratio 1:1.9) A = VS connections reverse-polarity protected.10) B = inputs and output reverse-polarity protected.11) C = interference suppression.
Mechanics
HousingRectangular
Design detailSlim
Dimensions (W x H x D)12.2 mm x 41.8 mm x 17.3 mm
ConnectionMale connector M8, 4-pin Material
HousingPlastic, Novodur
Front screenPlastic, PMMA
Weight100 g
Ambient data
Enclosure ratingIP66IP67
Ambient operating temperature–40 °C ... +60 °C
Ambient temperature, storage–40 °C ... +75 °C
UL File No.NRKH.E181493 ## Smart Task
Smart Task nameSpeed and Length Monitoring
Measurement modeSpeedLengthLength incremental
Relative measurement error related to the measured value≤ 1 %
Resolution measurement value1 mm / 1 mm/s
Logic functionWINDOW
Timer functionImpulse width, impulse shift
Max. pulse frequency at the external input (pin 2 / white wire)≤ 1,000 Hz Switching signal
Switching signal QL1Switching output to measuring value switching thresholds
Measuring valueSpeed measurement value / length measurement value ## Diagnosis
Device statusYes
Quality of teachYes
Quality of runYes, Contamination display ## Certificates
EU declaration of conformity
UK declaration of conformity
ACMA declaration of conformity
Moroccan declaration of conformity
China RoHS
China Compulsory Product Certification (CCC) exempt
ECOLAB certificate
IO-Link certificate
Photobiological safety (DIN EN 62471) certificate✔ ## Classifications