SICK PBT-RP100SG1SSNAMA0Z Pressure Sensors

SICK

SICK PBT-RP100SG1SSNAMA0Z Pressure Sensors

P/N: 6039267

SICK PBT-RP100SG1SSNAMA0Z Pressure Sensors — datasheet, specifications, part number lookup & authentic sourcing

Get a Quote / Inquire

Request a Quote Chat via WhatsApp Email Us

Overview

MediumLiquid, gaseous
Pressure typeGauge pressure
Pressure unitpsi
Measuring range0 psi ... 100 psi
Process temperature0 °C ... +80 °C
Maximum ohmic load RA4 mA ... 20 mA, 2-wire (RA ≤ (L+ - 8 V) / 0.02 A [Ohm]), 0 V ... 10 V, 3-wire (RA > 10 kOhm), 0 V ... 5 V, 3-wire (RA > 5 kOhm)
Output signal4 mA ... 20 mA, 2-wire

Specifications

Mechanics/electronics
Communication interface-
Process connectionG ¼ A (ISO 1179-2)
Wetted partsProcess connection: 316L stainless steel Measuring chamber: stainless steel 316L
Internal transmission fluidSilicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Pressure portStandard
Housing materialStainless steel
Connection typeM12 round connector x 1, 4-pin
Supply voltage8 V DC ... 30 V DC 1)
Power consumptionSignal current (max. 25 mA) for current output Max. 8 mA for voltage output signal
Electrical safetyOvervoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA Short-circuit protection: QA towards M Reverse polarity protection: L+ to M Protection class: III
Isolation voltage500 V DC
Weight sensorApprox. 80 g
SealNBR
Enclosure ratingIP67 2)
Protection class III
MTTF815 years
Pressure peak dampeningThrough integrated pressure port 0.6 mm or 0.3 mm for process connection G ¼ according to DIN 3852-E (0.3 mm at and above 10 bar)
Overvoltage protection36 V DC
Performance
Non-linearity≤ ± 0.5 %, (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy≤ ± 1 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2))
Adjustment accuracy of zero signal≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %)
Hysteresis≤ 0.16 % of the span
Non-repeatability≤ 0.1 % of the span
Response time< 4 ms
Signal noise≤ 0.3 % of the span
Long-term drift/one-year stability≤ 0.1 % of span to IEC 61298-2
Rated temperature range0 °C ... +80 °C
Service lifeMinimum 100 Mio. load cycles
Temperature error≤ ± 1.0% of the range, typ., ≤ ± 2.5% of the range max.
Reference conditionsReference conditions: According to IEC 61298-1
Ambient data
Ambient temperature, operation0 °C ... +80 °C
Storage temperature–40 °C ... +70 °C
Relative humidity45 % ... 75 %
Shock load500 g according to IEC 60068-2-27 (mechanical shock)
Vibration load10 g according to IEC 60068-2-6 (vibration under resonance) 20 g optional

Downloads