Overview

Product designationElectronic pressure sensor with analogue display
Applicationfor industrial applications
Process connectionthreaded connection G 1/2 external thread
Operating voltage DC18...32 V
Voltage typeDC
Electrical designPNP/NPN
Total number of outputs2
Output functionnormally open / normally closed; (parameterisable); analogue
Output signalswitching signal; analogue signal; (configurable)
Analogue current output4...20, invertible; (scalable) mA
Measuring range0...100 bar0...10 MPa
ConnectionM12 Connector
Materialsstainless steel (316L/1.4404); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm
Materials (wetted parts)Al2O3 (ceramics); FKM; stainless steel (316L/1.4404)
DisplayDisplay unit: 2 x LED green; switching status: LED yellow; switch points: LED ring red; function display: alphanumeric display red 4-digit; measured values: analogue display 0...350° rotatable, pointer not visible when unit disconnected; measured values: alphanumeric display red 4-digit
Ambient temperature-20...80 °C
Medium temperature-25...80 °C
Brandifm electronic gmbh or equivalent
TypePG2432

Specifications

Product characteristics
Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range
0...100 bar0...10 MPa
Process connectionthreaded connection G 1/2 external thread
Application
Special featureGold-plated contacts
Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C]-25...80
Min. burst pressure
700 bar70 MPa
Pressure rating
300 bar30 MPa
Type of pressurerelative pressure
Electrical data
Operating voltage[V]18...32 DC
Current consumption[mA]< 70; (24 V)
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]6
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V]2
Permanent current rating of switching output DC[mA]250
Switching frequency DC[Hz]75
Number of analogue outputs1
Analogue current output[mA]4...20, invertible; (scalable)
Max. load[Ω](Ub - 10 V) / 20 mA
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0...100 bar0...10 MPa
Set point SP
0.4...160 bar0.04...16 MPa
Reset point rP
0...159.6 bar0...15.96 MPa
Analogue start point
0...135 bar0...13.5 MPa
Analogue end point
25...160 bar2.5...16 MPa
In steps of
0.2 bar0.02 MPa
Accuracy / deviations
Switch point accuracy[% of the span]< ± 0,5; (Turn down 1:1)
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line)
Hysteresis deviation[% of the span]< ± 0,25; (Turn down 1:1)
Long-term stability[% of the span]< ± 0,1; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K]< ± 0,2; (0...70 °C)
Temperature coefficient span[% of the span / 10 K]< ± 0,2; (0...70 °C)
Response times
Response time[ms]< 9
Damping process value dAP[s]0.01...30
Damping for the analogue output dAA[s]0.01...30
Step response time analogue output[ms]28
Operating conditions
Ambient temperature[°C]-20...80
Storage temperature[°C]-40...100
ProtectionIP 67; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5/1 kV
EN 61000-4-6 HF conducted10 V
CPA approval
accuracy classClass 1.0
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-610 g (10...2000 Hz)
MTTF[years]97
UL approval
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]567.9
Dimensions[mm]169 x 100 x 57
Materialsstainless steel (316L/1.4404); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm
Materials (wetted parts)Al2O3 (ceramics); FKM; stainless steel (316L/1.4404)
Min. pressure cycles100 million
Process connectionthreaded connection G 1/2 external thread
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
Display
Display unit2 x LED, green
switching statusLED, yellow
switch pointsLED ring, red
function displayalphanumeric display, red 4-digit
measured valuesanalogue display, 0...350° rotatable, pointer not visible when unit disconnected
measured valuesalphanumeric display, red 4-digit
With scaleyes
Extended display range (max.)
160 bar16 MPa
Remarks
Remarks
switch point accuracy in the extended display range: 1.5 % of the span